CLJ-E laser dust particle counter, new model
关键词:
所属分类:
咨询热线:
CLJ-E laser dust particle counter, new model
CLJ-E laser dust particle counter, new model
New CLJ-E Laser Dust Particle Counter
The technical specifications of this series of instruments meet the requirements of the JJF1190-2008 calibration regulations issued by the State Administration of Metrology. The entire machine adopts American microcomputer control processing technology and can directly print the test results. It has the characteristics of multiple functions, high measurement accuracy, fast speed, easy portability, and simple operation. The instrument can simultaneously measure the number of dust particles of multiple sizes in one sampling, and can choose to observe the number and changes of particles of a certain size, which is very convenient for researching, detecting, and evaluating various clean environments. This series of products has been widely used in clean room testing; On site inspection and leak detection of filters; It can monitor ultra clean workbenches, HVAC systems, computer rooms, medical device production environments, hospital clean operating rooms, automotive spraying, pharmaceuticals, biochemical products, food hygiene, fine chemicals, precision machinery, aerospace and other production and research departments. It is an essential instrument for pharmaceutical companies and their supervisory management departments to implement GMP standards and for electronic production enterprises. This series of instruments has advanced performance design, stable and reliable quality
The new CLJ-E dust particle counter adopts a front 3-digit digital tube and a rear 8-bit digital tube display, which can display test data ranging from hundreds to millions. However, the counterfeit of our company's CLJ-E is modified from 20 years ago, with a front two digit digital tube and a rear digital tube consisting of only 6 digits, which can only display data up to 300000 levels. Falsely claiming to be able to test at the million level, in reality it is at the 300000 level.



1. Light source: Full semiconductor laser light source
2. Sampling volume: 2.83 L/min (0.1 cfm/min),
3. Counting efficiency: 0.3 μ m 50% ± 20 0.5 μ m 100% ± 10
4. Particle size concentration indication error: ± 10%
6. Particle size distribution error: ± 30%
7. Maximum sampling concentration: 30000 particles/L
8. Testing scope: Measurement of static and dynamic standards at levels A/B/C/D that comply with the new GMP standards, ranging from level 100 to level 1 million. Measurement of switching between four standards
Allow the tested air to have a dust concentration of no more than 100000 particles/2.83L
9. Particle size channel:
Standard particle size: 0.3 0.5 1.0 3.0 5.0 10.0 (μ m) six grades
If there are other particle size requirements, customization is available.
10. Six levels of particle size dust particles are detected simultaneously, with four display modes:
(1) Real time display: Real time display of real-time data for a certain particle size in the current detection
(2) Select Display: Select to display the cumulative value of a particle size from the previous cycle
(3) Cheng Xian: Display real-time data of each particle size in the current detection in sequence
(4) Sequential display: Display the cumulative values of each particle size in the previous cycle in sequence
11. Display or print can convert the particles contained in 2.83 liters/minute (0.1Ft3) into the number of particles contained in 28.3 liters/minute (1Ft3) or 1m3.
12. Sampling period: 1-10 (min) Self purification time:<10 min
13. Working environment: Temperature: 10-35 ℃ Relative temperature: 20-75% RH
14. Range and accuracy of measuring temperature and humidity: Choose (1) Temperature: 0-50 ℃± 1 ℃ (2) Humidity: 0-100% RH ± 5%
15. Sampling points (A) 2-7 points set, sampling times per point (L) 2-9 times set
16. UCL report: compliant with ISO14644-1 and GB50073-2001 standards
17. Working time: 8 hours Power supply: AC220V ± 10% 50 ± 2Hz Maximum power consumption: 20W
(1) Built in long-lasting lithium battery: capable of continuous measurement and operation for more than 8 hours, with an external charger that can quickly charge (<4 hours). The charger (optional) provides a power supply of 110V~220V, 50/60Hz
18. Data storage: It can store 1000 sets of data (including particle size, data, environmental data, year, month, day, time), and the data will not be lost after power failure. And data can be viewed and printed at any time.
19. Alarm setting: The instrument comes with a level alarm function, which can alarm for cleanroom levels 100, 1000, 10000, 100000, 300000, and 1000000 exceeding the standard
20. Standard configuration: built-in printer, printing paper, self-cleaning filter, power sampling head and rubber sleeve, sampling rack, sampling tube, user manual, factory inspection report, certificate of conformity, warranty card, R232 communication data cable and data acquisition software, charger, instrument special box (temperature and humidity probes are optional)
21. Calibration: JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification can be traced back to the National Institute of Standards and Technology (NIST) in the United States. Our company has passed the national metrology standard building assessment and can be traced back to the Shanghai Institute of Metrology and Measurement Technology, or can be calibrated by ourselves or by third-party national metrology institutions
22. Weight: 2.5kg. Dimensions: 200 × 110 × 280
CLJ-E is a dual-purpose semiconductor laser type that can be connected to a PC computer data acquisition system for remote control. It can directly observe the testing situation of the instrument, and the test data can be analyzed and processed by the computer and saved as an Excel file (this function is optional)