APC-3106T dual flow rate 28.3L/min dust particle counter
关键词:
所属分类:
咨询热线:
APC-3106T dual flow rate 28.3L/min dust particle counter
APC-3106T dual flow rate 28.3L/min dust particle counter
1. Light source: semiconductor laser
2. Sampling flow rate: 28.3L/min can be converted to 8.5L/min, with built-in flow sensor and automatic closed-loop flow control
3. Particle size channels: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0 μ m
4. Display: 7-inch capacitive touch screen
5. Power supply: Lithium battery rechargeable 14.8V 9.6A
6. Adopting DC brushless fan and PWM regulation control
7. Data storage: capable of storing 30000 sets of data
8. Printing function: Thermal printer
Product Features
This instrument was successfully developed in collaboration with Nanjing University of Science and Technology and other units in accordance with the requirements of the new version of GMP (2010 version)
Product. The overall shell of this product is made of 316L stainless steel. The laser sensor adopts full semiconductor laser and semiconductor
Photodiode receiver ensures the stability of the light source and the accuracy of the signal receiver. Greatly reduces the stray light inside the scattering cavity
By emitting light, the signal-to-noise ratio of the sensor is improved. Adopting LCD touch screen control, the display data is clear and the operation is convenient.
This instrument can automatically determine various purification levels based on the standards selected by the customer.
Scope of application
This product is widely used in medical, pharmaceutical, electronic, chemical, optical, food, cosmetics, biological products, aviation and aerospace industries
Tianhe and various testing institutions are used for the detection of dust particles.
Main technical parameters:
Light source semiconductor laser, with a lifespan of over 10 years>30000 hours
The sampling flow rate of 28.3L/min can be converted to 8.5L/min (1ft3) ± 5%, and the flow rate can be kept constant according to the length resistance of the sampling tube
Display mode: 155 × 85mm high-resolution capacitive touch screen with Chinese interface, real-time display, previous cycle display, real-time concentration display
It can display parameters such as time, date, measurement value, temperature and humidity, room number, sampling point, sampling frequency, status, etc., and calculate 95% UCL,
It can directly display particle concentration (particles/cubic meter) and has three-level permission management.
Power supply/working power maximum power consumption: 20W (1) Built in long-lasting lithium battery: can measure continuously for 3.5 hours, external charger can quickly charge, charging
The power supply of the device is 100V~220V, 50/60Hz
Working time 8 hours
Count mode cumulative value, difference value, concentration value
The testing method is single, repetitive, continuous, computational, and remote
Unit conversion: The unit can be converted to m3
Particle size channels 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0 μ m
Sampling period 1~9999 (S) Delay count: 0~9999 (S) Self purification time: ≤ 10 (min)
Working environment temperature: 0-40 ℃ (50-104 ℉) Relative temperature: 20-90% RH, no condensation Atmospheric pressure: 86-106KPa
Temperature and humidity: Choose (1) Temperature: 0-50 ℃± 1 ℃ (2) Humidity: 0-100% RH ± 5%
UCL sets the number of sampling points (A): 2-9 points are set. Sampling frequency per point: (L) 2-9 times Set measurement position: 0-9999
UCL report complies with ISO14644-1 2015, GB/T16292, GMP (2010), FS209E
The data storage can store 30000 sets of data (circular buffer), including particle size, data, environmental data, year, month, day, time, and sampling volume,
Data location port), data will not be lost after power failure.
Communication interface AB line, 9600 baud rate, USB interface
The alarm setting instrument has a level alarm function, which can alarm when the cleanroom exceeds the level of 100, 1000, 10000, 10000, 30000, 1000000
Switching measurement between four levels of static and dynamic standards, A/B/C/D, in compliance with the new GMP standards
Zero counting complies with JJF-1190-2008 Dust Particle Counter Metrology Calibration Specification and ISO/FDIS21501-4:2018, with less than one count every five minutes
Overlap error of 5%, at 2000000 particles per cubic foot
Printing function thermal printer
Weight 4.5kg
Calibration can meet the JJF-1190-2008 dust particle counter metrological calibration specification and GB/T6167-2007 dust particle counter performance test
The verification method and ISO/FDIS21501-4:2018 (E) cleanroom light scattering dust particle counter calibration method can be traced back to Shanghai
The Institute of Metrology and Measurement Technology can also perform calibration on its own or by third-party national metrology institutions, and can also trace back to American national standards
The National Institute of Technology (NIST). Our company has passed the national metrological standard assessment, and our standard dust particle counter has also participated in various provinces
National dust particle counter value comparison involving metrology institutions, and serving as a basis for relevant metrology and testing institutions to conduct dust particle counters
The use of standard precision particle counters during metrological calibration work.
Standard configuration includes professional power sampling head, sampling bracket with sampling tube, built-in printer, aluminum alloy box, operation manual, factory inspection report, zero
Counting filter, charger, sampling rack, printing paper
Dimensions 200 * 180 * 180 (mm)
Keywords: high traffic dust particle counter, dust particle counter, laser dust particle counter, convenient dust particle counter